Granite Dial Indicator Stand

A granite comparator stand that gives your indicator a reference face that does not move.

The base is a single block of natural black granite with a hand-lapped working face. The column and cross arm hold the indicator above the part: zero the indicator on a gauge block, swap in the workpiece, and read the difference — height, step height, parallelism and thickness variation are all comparative measurements. The base is heavy, rust-free and non-magnetic, so it sits dead still on the inspection bench and the reading stays put. Supplied with or without the indicator — dial, digital, lever-type and test indicators all fit. Non-standard base sizes and column heights are made to drawing.

150×150 – 300×250 mmgranite base sizes (design targets)
110 – 275 mmcolumn travel / measuring height
Ø8 / Ø9.53 mmindicator stem holes, plus dovetail clamp
Grade Ahand-lapped working face, flatness ≤ 3 µm target

Three Configurations in the Photo

The base is the same class of granite base on all three stands. What differs is the column and arm — pick by whether you need to set up fast or zero in fine.

Smooth column + cross arm — fast to set (left in the photo)

The column is a plain ground shaft. The cross block slides up and down and rotates around the column, the arm extends in and out, and the indicator head tilts — three directions, each locked by its own star knob. Changing parts or measuring points does not mean re-rigging the indicator. The trade-off: height has no scale and no fine feed, so zeroing is done by feel — pair it with the roughly 1 mm fine adjustment at the clamp and it works smoothly.

Threaded column — full-travel fine adjustment (center in the photo)

The column is threaded and the arm rides a nut along the full travel, so turning the handwheel feeds the arm down slowly and it never drops when you loosen your grip. Zeroing creeps up on the gauge block surface a fraction at a time — the right setup for 0.001 mm dial indicators and digital gauges. The trade-off is speed: large height changes take a lot of turns.

Clamp-head arm — takes stems and dovetails (right in the photo)

The arm ends in a clamp head: an Ø8 / Ø9.53 mm bore for dial and digital indicator stems, and a dovetail slot for lever-type test indicators. The head flips, so top faces, side faces and bore walls are all reachable by re-aiming the indicator. Best when one stand has to serve several different indicators — tell us which indicators you run and the bore and dovetail are matched before shipping.

Why a Granite Base

A comparator stand has one job: be the reference. A cast-iron base rusts and raises burrs when it is knocked; a magnetic base rides on the machine and vibrates with it. Granite answers each of those problems directly.

A reference face that knocks cannot ruin

If a workpiece strikes the working face, granite only chips a small pit — no raised burr, no lip. The face stays flat and parts still seat properly. A burred cast-iron face rocks every part placed on it.

No rust, no magnetism, no drift

Natural stone is stress-relieved over geological time. It does not rust and needs no oil film, it is non-magnetic so swarf does not cling to the measuring face, and it holds its accuracy for years without creeping.

Small thermal movement

With a linear expansion coefficient around 4.6×10−6/°C — less than half that of steel — normal shop temperature swings barely move the base size or flatness. Zero set in the morning is still zero in the afternoon.

Heavy enough to stay put

At roughly 3.0 g/cm³, a 200×250 mm base alone weighs well over 30 lb (about 14 kg with column and arm). It does not slide or rock on the bench, and the needle does not jump when someone bumps the table.

Property (black granite, typical) Typical value What it means for the stand
Density 2.97 – 3.07 g/cm³ Heavy, stable, vibration-damping base
Compressive strength 245 – 254 MPa No deformation under load
Linear expansion coefficient approx. 4.61×10−6 /°C Low thermal drift after zeroing
Water absorption < 0.13% Unaffected by humidity, no corrosion
Shore hardness Hs 70+ (Mohs 6 – 7) Wear resistant; scratches leave pits, not burrs

Note: material properties are published typical values for natural black granite (Jinan Green class). Flatness and measuring-height figures in the specification table below are design targets based on common granite comparator stands of this class; the measured values for each unit are stated in its inspection report.

Construction

Five assemblies, each replaceable on its own — a damaged part never scraps the whole stand.

Specifications — Design Targets

Four standard sizes cover comparative measurement from small stepped parts up to parts about 200 mm (8 in) tall. Larger bases and taller columns are made to drawing. Click-free reference table — the values below are design targets for this product class.

Model Base L×W×T (mm) Column travel / measuring height (mm) Throat depth (mm) Stem hole Working-face flatness (design target) Approx. weight (kg)
GS-1515 150 × 150 × 50 0 – 110 approx. 60 Ø8 / Ø9.53 Grade A, ≤ 3 µm approx. 5
GS-2015 200 × 150 × 50 0 – 200 approx. 85 Ø8 / Ø9.53 Grade A, ≤ 3 µm approx. 7
GS-2520 200 × 250 × 80 0 – 260 approx. 110 Ø8 / Ø9.53 / Ø20* Grade A, ≤ 3 µm approx. 14
GS-3025 300 × 250 × 80 0 – 275 approx. 120 Ø8 / Ø9.53 / Ø20* Grade A, ≤ 3 µm approx. 20

* The Ø20 stem hole suits large-stem gauges and linear probes — specify when ordering. Fine adjustment: approx. 1 mm at the clamp on the GS-1515 / 2015 / 2520; the GS-3025 is available with a threaded column for full-travel fine adjustment. Size ranges follow the common granite comparator-stand class (bases 150×150 to 300×250 mm, travel 110–275 mm); flatness is a ≤ 3 µm design target for all four sizes. Weights are estimated from granite density plus column and arm, and will vary.

Choosing a size

  • By part height: part height plus indicator mounting allowance must fit inside the travel. Parts under 100 mm are covered by the GS-1515 / 2015; parts around 200 mm need the 2520 / 3025.
  • By part footprint: the part must sit fully on the working face with room to move between measuring points. If the part is bigger than the base, go one size up or have the base made to the part.
  • By indicator resolution: a 0.01 mm dial indicator is fine on a smooth column; for 0.001 mm indicators, take fine adjustment so zeroing does not mean fiddling the lock knobs back and forth.

How It Works: Comparison Measurement in Four Steps

The stand never reads an absolute size — it reads how far a part sits from a standard. The standard is a gauge block, so step one is always zeroing.

  1. Clean and mount. Wipe the working face and the part’s seating face — one chip underneath is several micrometers of error. Clamp the indicator, aim the contact point at the measuring spot, lock every direction.
  2. Zero on a gauge block. Place a gauge block (or stack) of the nominal size under the contact point, lower the arm with a sensible preload, and bring the needle to zero with the fine adjustment. Lock down.
  3. Swap in the part and read the difference. Remove the block, place the part — the needle now shows how much larger or smaller than nominal the part is. Read point by point; the largest spread across points is your parallelism / flatness indication.
  4. Re-check before you finish. Put the gauge block back and confirm zero has not drifted. If it has, re-measure the batch; if it has not, wipe the face clean and park the indicator raised.

Applications

Height and step height

Comparative height and step measurement of shafts, sleeves and mold inserts — at the line side and in the inspection room.

Parallelism and flatness checks

Sweep the indicator across the part on the base face and watch the reading spread for a fast in/out judgment on parallelism and flatness.

Wall thickness and runout work

With a lever indicator for wall-thickness variation and face runout; add a V-block and the same base extends to radial runout checks on cylindrical parts.

A small reference bench

The working face is itself a small granite surface plate — with no indicator mounted it serves for layout, lapping checks and visual inspection of small parts.

Care & Maintenance

Day to day

Wipe the working face with a clean soft cloth (a little alcohol is fine) before use. Set parts down gently — never drag them across the face. Raise the indicator when finished; do not leave the contact point loaded on the face.

Storage

Cover with the dust cover, store flat, nothing stacked on top. Granite does not rust and needs no oil — an oil film only hurts measurement. The steel column and knobs take a thin wipe of rust preventive.

Knocks and chips

A chipped pit does not affect use. If the edge of a pit is slightly raised, stone the raised part down gently with a fine oilstone and wipe clean — never grind the whole face.

Calibration

Re-check working-face flatness and column squareness on a cycle matched to use — annually in typical service, every 6 months in high-frequency use, and immediately after an impact or relocation. A worn face can be re-lapped back to grade; the base does not need replacing.

Frequently Asked Questions

Granite stand or magnetic base — which should I buy?

They do different jobs. A magnetic base sticks to a machine or steel table and travels with the equipment — flexible, but its accuracy depends on the mounting surface and the machine. A granite stand carries its own lapped reference face: it is an independent comparative-measurement setup for the inspection room and line-side inspection stations where repeatability matters. Use magnetic bases for on-machine indicating; use a granite stand when the numbers go on a report.

Is the indicator included? What indicators fit?

Stand and indicator are priced separately — buy the stand alone and use the indicators you already own. The clamp takes Ø8 / Ø9.53 mm stems and dovetail lever indicators, covering common dial, digital and test indicators. For unusual stem sizes, specify when ordering and we fit a Ø20 bore or a bushing.

What does Grade A flatness mean — is it enough?

Grade A is the inspection grade in the granite surface-plate grading system (AA laboratory grade is the highest, then A, then B toolroom grade). The design target for these bases is a working-face flatness of ≤ 3 µm — smaller than the 0.001 mm resolution of a typical test indicator, so the base does not dominate the error budget of a comparative measurement. Every unit ships with an inspection report stating its measured values.

Smooth column or threaded column?

For speed, the smooth column: loosen, slide, lock — part changes are quick. For fine reading, the threaded column: the arm feeds slowly over the full travel and zeroing takes no effort, which suits 0.001 mm indicators and electronic gauges. Bases and clamps are common to both, so one station can run one of each.

Can you make one to my part?

Yes. Base footprint and thickness, column height and stem bore are all made to drawing, and threaded inserts or locating slots can be added to the base. Send the part dimensions, what you need to measure, and the indicator you use — we confirm a proposal drawing before production.

What ships in the crate?

The complete stand (base, column, arm, clamp), the working-face inspection report and a dust cover, in a wooden crate. Granite edges chip if dropped, so packing follows precision-gauge practice with corner protection — inspect the edges and working face before signing for delivery.

—— LET'S COLLABORATE BUILD PRECISION INTO YOUR NEXT PROJECT

Share your application, drawing or dimensional requirements with our team.

Request a Quote →
Request a QuoteTell Us What You're Building

Export-grade crating and partner logistics keep heavy precision parts safe across North America, Europe and Asia-Pacific.

  • √Engineering response within 1 business day
  • √Standard plates from 7 days · custom builds from 20 days
  • √Drawings in STEP, DWG or PDF — NDA on request
  • √Prefer email? Write to info@bostar-motioncore.com
Get Your Quotation

Three fields is all it takes to start.